Condition Survey for M&E Main Plants for Crowne Plaza Hong Kong Causeway Bay
We are engaged in the condition survey for M&E Main Plants for Crowne Plaza Hong Kong in Causeway Bay. The hotel is with 263 guest rooms and has been operating since 2009. Talent carries out condition surveys and functional tests for existing M&E main plants including chiller plant system, air handling system, main switchboards, plumbing & drainage system, fire services system, filtration System of swimming pool, building management system, etc. Recommendations are proposed to improve the present situation and to re-commission the existing systems to enable the smooth and efficient operations of the M&E Systems.

 PCCW SPOF Anaysis for Data Centre at Cyberport
The scope of consultancy comprises the review of the whole M&E Systems, focusing on system reliability, redundancy, diversity and control safety. Talent also provides the single point of failure study to evaluate the performance of the whole M&E Systems.

 Another Energy Audit Projects in Hong Kong
With the methodology developed in our past energy audit and energy saving projects, we are engaged to carry out another energy audit for 5 premises for Hang Lung Project Management and Harriman Property this year. Again, the project team is headed by our Associate Ir. Dora Ho who has many years of experiences on energy saving and energy audit. Team members Ms Bella Lui, Mr KW Wong, Ms SP Wan and Mr. HM Lee also have extensive experiences on this area. As the study and reporting duration took a short period of time, several engineers are assigned to assist the field data collections and analytical studies. Through working on detailed data collections and studies, it was another good chance to train our young engineers on energy usage and energy savings.
 Single Point of Failure Study for Data Centre at Shatin, H.K.
The equipment room of 330m2 within the 4,000m2 Data Centre requires services provisions of extremely high reliability. The study undertaken by Talent is to evaluate the effect of any Single Point of Failure in the electrical and mechanical systems, and telecommunication containment system so as to modify the design to increase system reliability together with emergency response procedures.

 Feasibility Study on Fire Safety for Unmanned Plant of the CL&P Power Plant at Penny’s Bay, Lantau Island, H.K.
The Power Plant in Penny’s Bay is a stand-by power plant. It is run occasionally to up-keep the conditions of the equipment. The scope of consultancy includes the study on fire safety and the associated precautions and installations to enable the conversion of the plant to un-manned operation.

 Plant Conditions Audit for Tsim Sha Tsui Centre, TST, H.K.
The building is a mixed use premises with shopping arcades at podium levels and offices on upper floors with total floor area of around 82,000m2. Part of consultancy work is the condition audit of the M & E system and plants which includes the analysis of fresh water quality, corrosion conditions of chilled water pipes, seawater cooling systems, chlorination system, electrical distribution and illumination levels etc.

 Replacement of Chillers for Tsim Sha Tsui Centre and Empire Centre, TST, Kln., H.K.
The two buildings have been put into operations for around 15 years. Total floor area of the two building is around 115,000m2 with total cooling capacity of around 4,000T.R. The scope of consultancy includes the condition audits, energy analysis and detail design for the replacement of the chillers and the associated components etc.
 
 